1.Wide Frequency-band sound-absorbing suspended ceiling
A.Structural floor
B. Tendon-suspended, light-steel keels with hollow cavity. (≥100mm)
C. Sound-absorbing layer of centrifugal glass wool panel in 50mm thick.
D. Perforated LCFC (NALC) panels of 5-8mm thick.
Perforating rate: ≥16% Aperture: ¢6-8
2.Low Frequency-band sound-absorbing ceiling
A. Structural floor.
B.Tendon-suspended, light-steel keels with hollow cavity. (≥200mm)
C. Perforated LCFC (NALC) panels of 5-8mm thick.Perforating rate: 0.5-4% Aperture: ¢4-8
D.The panel is covered with a layer of glass wool cloth or yarn free clot
3.Middle- and high- frequency sound-absorbing ceiling
A. Structural floor.
B. Light-steel keels of 50mm or 75mm.
C. Sound-absorbing layer of centrifugal glass wool panel in 50mm-70mm thick. (including glass fiber hop-pocket ), (Density: 24-32kg/m3).
D. Perforated LCFC (NALC) panels in 5-8mm thick.
Perforating rate: ≥16% ; Aperture: ¢6-8
The surface is covered with coatings or sound-transparent cloth